Con-cur Dryer Current Sensor
These are the same controls used in more than a quarter million condos/apartments. Con-Cur senses as soon as your clothes dryer draws more than 1 amp of current. It automatically turns on your dryer booster fan, eliminating additional sensors, switches, or speed controls. When current drops below the pre-set 2-amp threshold, the Con-Cur Dryer Current Sensor automatically shuts off the booster fan. Mount it:
- inside your dryer compartment, or
- at the dryer junction box
The dryer supply neutral (white) wire passes through the current transformer cutout with no physical connection to the control.
IMPORTANT: A licensed electrician is the best person to install this equipment. Be sure to adhere to local provisions and national electrical codes. Verify industry standards prior to installation.
DISCLAIMER: Note that some low voltage dryers operate at a lower voltage, and as such, Con-Cur current sensors must be field tested for the specific model in operation. infraAIR is not responsible for any compatibility issues or installation costs incurred. This includes any legal claims or lawsuits arising from such issues. Our standard return policies, as posted on our website, apply. The field test must be conducted by a licensed electrician to confirm that the new dryer operates correctly with the relay according to the dryer cycle.
Features
- Self-powered cuts installation and operating costs.
- Safe and reliable.
- Easy for installation.
- Solid-state switch for control circuits up to2.5A @120 VAC/DC.
- Designed to meet CSA approval.
- The shell is made of ABS (UL 94V-0).
- Adjustable set trip point from 0.5 to 50A.
- Power MOS act as a switch device in the designed of the switch.
- The number of startup is not limited.
- The response time of the switch less than 200ms.
- Solid-core or split-core design, the isolation voltage up to 2000V.
Specifications
Input Range | 1.25 – 40 Amp-turns |
Hysteresis | <1% FS Max |
Op.Temperature | 0 – 40 °C (32-104°F) |
Op. Humidity | 0-95% RH Non-condensing |
Trip Set-Point | Factory pre-set at approximately 1.25 Amps |
Material | Self-Extinguishing ABS (Cycolac 94V-0) |
HxWxD | 70x89x28 mm (2.75×3.5×1.1 in) MAX |
Mounting Holes | 2x5mm holes spaced 76mm (2×0.19 in. holes spaced 3 in.) |
AC Cond. Hole | 19mm (0.75in) Ø |
Output Type | Triac |
Switch Rating | 120 VAC @ 2.5 Amps Max |
Leakage Current | < 1mA |
Core Current | 1.25 – 40 Amps Continuous |
Installation Procedure
INSTALLATION MODEL 1 1. Mount the Con-Cur current sensor in convenient location inside dryer connection compartment. |
|
INSTALLATION MODEL 2 1. Attach electrical junction box to dryer junction box.
|